-40%

Fluke 753 / ISO 17025 Calibration with warranty

$ 2320.56

Availability: 39 in stock
  • Non-Domestic Product: No
  • Model: 753
  • Modified Item: No
  • Custom Bundle: No
  • Item must be returned within: 30 Days
  • Brand: Fluke
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • Condition: Fluke 753 Documenting Process Meter with ISO-17025 Calibration report (4 pages of data points)
  • All returns accepted: Returns Accepted
  • Country/Region of Manufacture: United States
  • Refund will be given as: Money back or replacement (buyer's choice)
  • MPN: 753

    Description

    Fluke 753 Overview
    The 753 is everything you needed and wished for in the 743B and more!
    The 753 does the work of several tools – sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. You’ll fall in love with the new improved graphical screen, Li-Ion battery for longer life, USB port and new accessories to complete the package.
    For documentation, the 753 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations.
    Want HART communication built into your 753 calibrator? Consider the
    Fluke 754
    Documenting Process Calibrator with HART.
    Measurement Accuracy
    Voltage DC
    Range /Resolution
    1 Year
    2 Years
    100.000 mV
    0.02% + 0.005 mV
    0.03% + 0.005 mV
    3.00000 V
    0.02% + 0.00005 V
    0.03% + 0.00005 V
    30.0000 V
    0.02% + 0.0005 V
    0.03% + 0.0005 V
    300.00 V
    0.05% + 0.05 V
    0.07% + 0.05 V
    Voltage AC
    3.000 V (40 Hz to 500 Hz) / 0.001 V
    0.5% + 0.002 V
    1.0% + 0.004 V
    30.00 V (40 Hz to 500 Hz) / 0.01 V
    0.5% + 0.02 V
    1.0% + 0.04 V
    300.0 V (40 Hz to 500 Hz) / 0.1 V
    0.5% + 0.2 V
    1.0% + 0.2 V
    Current DC
    30.000 mA
    0.01% + 5 uA
    0.015% + 7 uA
    110.00 mA
    0.01% + 20 uA
    0.015% + 30 uA
    Resistance
    10.000 Ω
    0.05% + 50 mΩ
    0.07% + 70 mΩ
    100.00 Ω
    0.05% + 50 mΩ
    0.07% + 70 mΩ
    1.0000 kΩ
    0.05% + 500 mΩ
    0.07% + 0.5 Ω
    10.000 kΩ
    0.1% + 10 Ω
    0.15% + 15 Ω
    Frequency
    1.00 to 110.00 Hz / 0.01 Hz
    0.05 Hz
    110.1 to 1100.0 Hz / 0.1 Hz
    0.5 Hz
    1.101 to 11.000 kHz / 0.001 kHz
    0.005 kHz
    11.01 to 50.00 kHz / 0.01 kHz
    0.05 kHz
    Source Accuracy
    1 Year
    2 Years
    Voltage DC
    100.000 mV
    0.01% + 0.005 mV
    0.015% + 0.005 mV
    1.00000 V
    0.01% + 0.00005 V
    0.015% + 0.0005 V
    15.0000 V
    0.01% + 0.0005 V
    0.015% + 0.0005 V
    Current DC
    22.000 mA (source)
    0.01% + 0.003 mA
    0.02% + 0.003 mA
    Current sink (simulate)
    0.02% + 0.007 mA
    0.04% + 0.007 mA
    Resistance
    10.000 Ω
    0.01% + 10 mΩ
    0.015% + 15 mΩ
    100.00 Ω
    0.01% + 20 mΩ
    0.015% + 30 mΩ
    1.0000 kΩ
    0.02% + 0.2 Ω
    0.03% + 0.3 Ω
    10.000 kΩ
    0.02% + 3 Ω
    0.03% + 5 Ω
    Frequency
    0.1 to 10.99 Hz
    0.01 Hz
    0.01 to 10.99 Hz
    0.01 Hz
    11.00 to 109.99 Hz
    0.1 Hz
    110.0 to 1099.9 Hz
    0.1 Hz
    1.100 to 21.999 kHz
    0.002 kHz
    22.000 to 50.000 kHz
    0.005 kHz
    Technical Data
    Data log functions
    Measure functions
    Voltage, current, resistance, frequency, temperature, pressure
    Reading rate
    1, 2, 5, 10, 20, 30, or 60 readings/minute
    Maximum record length
    8000 readings (7980 for 30 or 60 readings/minute)
    Ramp functions
    Source functions
    Voltage, current, resistance, frequency, temperature
    Rate
    4 steps/second
    Trip detect
    Continuity or voltage (continuity detection not available when sourcing current)
    Loop power function
    Voltage
    Selectable, 26 V
    Accuracy
    10%, 18 V minimum at 22 mA
    Maximum current
    25 mA, short circuit protected
    Maximum input voltage
    50 V DC
    Step functions
    Source functions
    Voltage, current, resistance, frequency, temperature
    Manual step
    Selectable step, change with arrow buttons
    Autostep
    Fully programmable for function, start delay, stepvalue, time per step, repeat
    Environmental Specifications
    Operating temperature
    -10°C to +50°C
    Storage temperature
    -20°C to +60°C
    Dust/water resistance
    Meets IP52, IEC 529
    Operating altitude
    3000 m above mean sea level (9842 ft)
    Safety Specifications
    Agency approvals
    CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993
    Mechanical and General Specifications
    Size
    136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in)
    Weight
    1.2 kg (2.7 lb)
    Batteries
    Internal Battery Pack Li-ion: 7.2 V, 4400 mAh, 30 Wh
    Battery life
    > 8 hours typical
    Battery replacement
    Via snap-shut door without opening calibrator; no tools required
    Side port connections
    Pressure module connector
    USB Connector to interface to your PC
    Connection for optional battery charger/eliminator
    Data storage capacity
    1 week of calibration procedures results
    90 day specifications
    The standard specification interval for the 750 Series are 1 and 2 years.
    Typical 90 day measurement and source accuracy can be estimated by dividing the one year "% of reading" or "% of output" specifications by 2.
    Floor specifications, expressed as "% of full scale" or "counts" or "ohms" remain constant.
    Temperature, Resistance Temperature Detectors
    Degrees or % of reading - Type (α)
    Range °C
    Measure °C1
    1 year
    2 year
    100 Ω Pt (385)
    -200 to 100
    0.07°C
    0.14°C
    100 to 800
    0.02% + 0.05°C
    0.04% + 0.10°C
    200 Ω Pt (385)
    -200 to 100
    0.07°C
    0.14°C
    100 to 630
    0.02% + 0.05°C
    0.04% + 0.10°C
    500 Ω Pt (385)
    -200 to 100
    0.07°C
    0.14°C
    100 to 630
    0.02% + 0.05°C
    0.04% + 0.10°C
    1000 Ω Pt (385)
    -200 to 100
    0.07°C
    0.14°C
    100 to 630
    0.02% + 0.05°C
    0.04% + 0.10°C
    100 Ω Pt (3916)
    -200 to 100
    0.07°C
    0.14°C
    100 to 630
    0.02% + 0.05°C
    0.04% + 0.10°C
    100 Ω Pt (3926)
    -200 to 100
    0.08°C
    0.16°C
    100 to 630
    0.02% + 0.06°C
    0.04% + 0.12°C
    10 Ω Cu (427)
    -100 to 260
    0.2°C
    0.4°C
    120 Ω Ni (672)
    -80 to 260
    0.1°C
    0.2°C
    Source current
    Source °C
    Allowable current2
    1 year
    2 year
    1 mA
    0.05°C
    0.10°C
    0.1 mA to 10 mA
    0.0125% + 0.04°C
    0.025% + 0.08°C
    500 μA
    0.06°C
    0.12°C
    0.1 mA to 1 mA
    0.017% + 0.05°C
    0.034% + 0.10°C
    250 μA
    0.06°C
    0.12°C
    0.1 mA to 1 mA
    0.017% + 0.05°C
    0.034% + 0.10°C
    150 μA
    0.06°C
    0.12°C
    0.1 mA to 1 mA
    0.017% + 0.05°C
    0.034% + 0.10°C
    1 mA
    0.05°C
    0.10°C
    0.1 mA to 10 mA
    0.0125% + 0.04°C
    0.025% + 0.08°C
    1 mA
    0.05°C
    0.10°C
    0.1 mA to 10 mA
    0.0125% + 0.04°C
    0.025% + 0.08°C
    3 mA
    0.2°C
    0.4°C
    0.1 mA to 10 mA
    1 mA
    0.04°C
    0.08°C
    0.1 mA to 10 mA
    1. For two and three-wire RTD measurements, add 0.4°C to the specifications.
    2. Supports pulsed transmitters and PLCs with pulse times as short as 1 ms
    Temperature, Thermocouples
    Type
    Source °C
    Measure °C
    Source °C
    1 year
    2 years
    1 year
    2 years
    E
    -250 to -200
    1.3
    2
    0.6
    0.9
    -200 to -100
    0.5
    0.8
    0.3
    0.4
    -100 to 600
    0.3
    0.4
    0.3
    0.4
    600 to 1000
    0.4
    0.6
    0.2
    0.3
    N
    -200 to -100
    1.0
    1.5
    0.6
    0.9
    -100 to 900
    0.5
    0.8
    0.5
    0.8
    900 to 1300
    0.6
    0.9
    0.3
    0.4
    J
    -210 to -100
    0.6
    0.9
    0.3
    0.4
    -100 to 800
    0.3
    0.4
    0.2
    0.3
    800 to 1200
    0.5
    0.8
    0.3
    0.3
    K
    -200 to -100
    0.7
    1
    0.4
    0.6
    -100 to 400
    0.3
    0.4
    0.3
    0.4
    400 to 1200
    0.5
    0.8
    0.3
    0.4
    1200 to 1372
    0.7
    1
    0.3
    0.4
    T
    -250 to -200
    1.7
    2.5
    0.9
    1.4
    -200 to 0
    0.6
    0.9
    0.4
    0.6
    0 to 400
    0.3
    0.4
    0.3
    0.4
    B
    600 to 800
    1.3
    2
    1
    1.5
    800 to 1000
    1
    1.5
    0.8
    1.2
    1000 to 1820
    0.9
    1.3
    0.8
    1.2
    R
    -20 to 0
    2.3
    2.8
    1.2
    1.8
    0 to 100
    1.5
    2.2
    1.1
    1.7
    100 to 1767
    1
    1.5
    0.9
    1.4
    S
    -20 to 0
    2.3
    2.8
    1.2
    1.8
    0 to 200
    1.5
    2.1
    1.1
    1.7
    200 to 1400
    0.9
    1.4
    0.9
    1.4
    1400 to 1767
    1.1
    1.7
    1
    1.5
    C
    0 to 800
    0.6
    0.9
    0.6
    0.9
    800 to 1200
    0.8
    1.2
    0.7
    1
    1200 to 1800
    1.1
    1.6
    0.9
    1.4
    1800 to 2316
    2
    3
    1.3
    2
    L
    -200 to -100
    0.6
    0.9
    0.3
    0.4
    -100 to 800
    0.3
    0.4
    0.2
    0.3
    800 to 900
    0.5
    0.8
    0.2
    0.3
    U
    -200 to 0
    0.6
    0.9
    0.4
    0.6
    0 to 600
    0.3
    0.4
    0.3
    0.4
    BP
    0 to 1000
    1
    1.5
    0.4
    0.6
    1000 to 2000
    1.6
    2.4
    0.6
    0.9
    2000 to 2500
    2
    3
    0.8
    1.2
    XK
    -200 to 300
    0.2
    0.3
    0.2
    0.5
    300 to 800
    0.4
    0.6
    0.3
    0.6
    Fluke 753 Includes
    Three sets of stackable test leads
    Three sets of TP220 test probes with three sets of “extended tooth” alligator clips
    Two sets AC280 hook clips
    BP7240 Li-ion battery pack
    BC7240 battery charger
    C799 field soft case
    USB communication cable
    Getting started guide
    Instruction manual on CDROM
    calibration (ISO-17025)
    30 days Warranty
    Returns accepted.
    Shipments within Canada subject to 5% GST & shipments within Ontario subject to 13% HST.  Please contact us for a quote